SystemSure Plus™ ATP Luminometer

$2,100.00

The SystemSURE PLUS ATP Meter is a tool that will help any environmental investigator or restoration contractor provide their customers with immediate feedback and decision-making capability.

The SystemSURE PLUS Luminometer measures Adenosine Triphosphate (ATP), the universal energy molecule found in all animal, plant, bacterial, yeast, and mold cells.

INCLUDES:

  • Luminometer with Stand (SS3H)
  • Protective Case(SSCC01)
  • Manual + System Implementation Guide
  • Data Analysis Software

Hygiena UltraSnap™ ATP Surface Test Swab (100 PK) sold separately: Click here to purchase

 

Description

KEY FEATURES:

  • Alphanumeric sample location programming
  • SureTrend data analysis software included
  • Detects down to 1 Femtomole of ATP
  • Self-contained and aseptic
  • Programmable pass/fail levels
  • Stores up to 1,000 individual test results
  • 250 programmable test locations
  • Battery powered (standard AA)
  • 1,000-2,000 tests per battery/charge
  • Most cost-effective ATP hygiene monitoring system available
  • Provides real-time feedback and facilitates long-term data analysis
  • Optimizes and verifies that cleaning procedures are working
  • Assists in developing and improving process and risk assessment programs (ie. HACCP & GMPs)
  • No data loss if battery or power failure
  • Range of instrument reading: 0-9,999 RLUs
  • Produces test results in 15 seconds
  • Durable (withstand 1-meter drop test)
  • Results displayed in RLUs or icons (pass/fail/caution)
  • Dimensions (approx.): 7 x 3 x 1 inches

Directions for Use

  1. Using an Ultrasnap testing device, take a swab sample of an area about 4 inches squared or 10 centimeters squared. (Or the equivalent on an uneven surface.) The Ultrasnap swabs come pre-moistened with special liquid that breaks down biofilm and exposes ATP.  Or collect a water sample with an Aquasnap testing device. (Aquasnap devices will have slightly different directions.)
  2. Place Ultrasnap swab back into swab tube.
  3. Holding the swab tube firmly, use your thumb and forefinger to break the snap valve on the tube by bending it back and forth.
  4. Squeeze the end bulb twice, expelling all of the liquid down the swab shaft.
  5. Bathe swab bud in the liquid (this is a testing reagent) by shaking the tube for 5 seconds.
  6. Open lid on SystemSURE and place Ultrasnap tube into testing chamber and close lid.
  7. Press OK button to initiate reading. Results will be displayed in 15 seconds.
  8. Read results.
    1. Easy to understand PASS (check mark) CAUTION (!) or FAIL (X) symbols make results easy to understand immediately.
    2. Results are displayed in Relative Light Units (RLU). More contamination = higher RLU results.
    3. Programmed location names for each sample are displayed on the screen, along with a location number, making it easy to tell where each testing sample came from. Up to 251 location names can be programmed.
    4. Upper and lower pass/fail limits are set for each location and are displayed on screen.
    5. 20 sample plans can be created. Each sample plan has specific programmed locations that should be tested when running a particular plan.
    6. User identification can be assigned to track performance and traceability.
  9. SystemSURE Plus comes with SURE-Trend data analysis and charting software so you can connect it with your computer and make a database of what you have tested.

Additional information

Weight 2 lbs
Dimensions 9 × 10.5 × 3.5 in

Reviews

There are no reviews yet.

Be the first to review “SystemSure Plus™ ATP Luminometer”

Your email address will not be published. Required fields are marked *

Title

Go to Top