• The Allergenco-D IAQ air sampling cassette was developed for the sampling and collection of aeroallergens and bioaerosols for quantitative analysis of mold spores, pollen, skin fragments, insects, dusts, and other airborne particulates. It has a well-designed impaction trace and collects at a rate of 15 liters per minute.
     
  • The dust collector is a molded plastic device (with an inner capture basket) that fits onto the wand of most vacuum cleaners. Used to take samples of indoor molds and allergens. Click here for EPA sampling instructions for ERMI
  • Designed for use with the SystemSURE PLUS™ ATP Measurement System (ATP Meter). UltraSnap™ ATP Surface Test Swab is a user-friendly, all-in-one ATP sampling test used with Hygiena luminometers. This pen-sized sample collection device is easy to use, small, and environmentally friendly. In addition, UltraSnap uses a unique liquid-stable reagent providing superior accuracy, longer-lasting signal strength, and more reproducible results.
    • UltraSnap™ has a shelf life of 15 months at refrigerated temperatures and 4 weeks at room temperature.
    • UltraSnap™ is made of 100% recyclable plastic, used devices may be discarded in the recycle bin.
      Perishable, MUST ship Priority Over Night   SystemSURE PLUS ATP Meter sold separately: Click here to purchase    
  • Designed for use with the SystemSURE PLUS™ ATP Measurement System (ATP Meter). UltraSnap™ ATP Surface Test Swab is a user-friendly, all-in-one ATP sampling test used with Hygiena luminometers. This pen-sized sample collection device is easy to use, small, and environmentally friendly. In addition, UltraSnap uses a unique liquid-stable reagent providing superior accuracy, longer-lasting signal strength, and more reproducible results.
    • UltraSnap™ has a shelf life of 15 months at refrigerated temperatures and 4 weeks at room temperature.
    • UltraSnap™ is made of 100% recyclable plastic, used devices may be discarded in the recycle bin.
      Perishable, MUST ship Priority Over Night   SystemSURE PLUS ATP Meter sold separately: Click here to purchase    
  • Designed for use with the SystemSURE PLUS™ ATP Measurement System (ATP Meter). UltraSnap™ ATP Surface Test Swab is a user-friendly, all-in-one ATP sampling test used with Hygiena luminometers. This pen-sized sample collection device is easy to use, small, and environmentally friendly. In addition, UltraSnap uses a unique liquid-stable reagent providing superior accuracy, longer-lasting signal strength, and more reproducible results.
    • UltraSnap™ has a shelf life of 15 months at refrigerated temperatures and 4 weeks at room temperature.
    • UltraSnap™ is made of 100% recyclable plastic, used devices may be discarded in the recycle bin.
      Perishable, MUST ship Priority Over Night   SystemSURE PLUS ATP Meter sold separately: Click here to purchase    
  • The M-TRAP® is a unique air sampling cassette developed specifically for the rapid capture and analysis of airborne fungi, bacteria, and viruses using state-of-the-art DNA & RNA analysis. It embodies the next generation of capture technology for residential and occupation mold exposure assessment. The M-TRAP® excels where spore trap and agar impaction falls short —spore capture efficiency and turnaround time. The cassette is designed to follow a color-coded system. The blue striped  M-TRAP® are labeled to capture airborne fungi and bacteria. The red striped M-TRAP® are labeled to capture airborne viruses. M-TRAP® may be connected via 1/4” tubing commonly used with air sampling pumps that are currently on the market. It is also compatible with the Buck BioAire Pump and the Zefon Bio-Pump (an adapter is required for use of the Zefon Bio Pump).
    In order to submit samples using our red M-TRAP® cassette, all clients must first contact the lab to complete an account form. Any and all shipping will be processed on weekdays during hours of operation. Any item purchased after 3:30 pm EST will be processed the following business day.

    Learn how to collect your sample

  • Now inspectors who operate under the Zefon Bio Pump can expand into DNA & RNA air sampling by using the M-TRAP® Zefon Bio Pump Adapter. The M-TRAP® is a unique air sampling cassette developed specifically for the rapid capture and analysis of airborne fungi, bacteria, and viruses using state-of-the-art DNA & RNA analysis. Simply attach your adapter to your Zefon Bio Pump, connect your M-TRAP®, and begin sampling! The M-TRAP® is compatible with the Buck BioAire Pump and can be connected via 1/4” tubing commonly used with air sampling pumps that are currently on the market (such as the MegaLite IAQ Air Sampling Pump). Any and all shipping will be processed on weekdays during hours of operation. Any item purchased after 3:30 pm EST will be processed the following business day.
  • The Micro5 was pioneered to evenly collect aeroallergens such as pollens, mold & fungal spores, fibers, dander, insect components and other airborne contaminants. It has an exceptionally uniform collection trace and is designed to operate at a flow rate of 5 liters per minute.
  • This adapter was designed as an attachment for the spore trap cassette to ease inner wall sampling.  Comes in a pack of 10.